• Plastic box 220x275x140 grey RAL 7035.
  • Level relay (RND20) of the AVEL brand for monitoring the water level.
  • Power supply (FAL16) brand AVEL 16 VA 230V/24V.
  • Alarm Module (MCS-AL) of the Brand AVEL for audible and luminous warning of accumulation of fats or lack of water in the reservoir.
  • Protection against short circuits through circuit breaker.
  • Alarm information on (red ALARM MODULE LED).
  • alarm operating switch in automatic (AUT), off (0) or manual(1)) (alarm module)

After all connections have been made correctly, the frame must display all the signs switched off until the circuit breaker is switched on, at which time the RND20 Yellow Led (24V-) turns on.

The level relay (RN020) monitors the water level in the tank through the probes.

Whenever the water ceases to come into contact with one of the probes due to the accumulation of fats or lack of water, the RND20 relay gun (10-12) by connecting the red beacon and the audible alarm in the MCS-AL alarm module, which can be switched off by means of the respective Switch.

Control of fat level in Hydrocarbon Separators and Fat Separators

Presentation
  • Plastic box 220x275x140 grey RAL 7035.
  • Level relay (RND20) of the AVEL brand for monitoring the water level.
  • Power supply (FAL16) brand AVEL 16 VA 230V/24V.
  • Alarm Module (MCS-AL) of the Brand AVEL for audible and luminous warning of accumulation of fats or lack of water in the reservoir.
  • Protection against short circuits through circuit breaker.
  • Alarm information on (red ALARM MODULE LED).
  • alarm operating switch in automatic (AUT), off (0) or manual(1)) (alarm module)
Operation

After all connections have been made correctly, the frame must display all the signs switched off until the circuit breaker is switched on, at which time the RND20 Yellow Led (24V-) turns on.

The level relay (RN020) monitors the water level in the tank through the probes.

Whenever the water ceases to come into contact with one of the probes due to the accumulation of fats or lack of water, the RND20 relay gun (10-12) by connecting the red beacon and the audible alarm in the MCS-AL alarm module, which can be switched off by means of the respective Switch.

Applications

Control of fat level in Hydrocarbon Separators and Fat Separators