MISCELLANEOUS
Hydrocarbon separator and grease separator Alarm panel
Features
- Various
- Hydrocarbon separator and grease separator Alarm panel
Presentation
- Plastic housing 220x275x140 grey RAL 7035.
- AVEL level relay (RND20) for monitoring the water level.
- Power supply unit (FAL16) from AVEL 16 VA 230V/24V.
- Alarm Module (MCS-AL) from AVEL for audible and light warning of grease accumulation or lack of water in the tank.
- Short-circuit protection by circuit breaker.
- Alarm indication on (red LED of the alarm module).
- switch for alarm operation in automatic (AUT), off (0) or manual(1)) (alarm module)
Operation
Once all the connections have been made correctly the panel should display all signs off until the circuit breaker is switched on, at which point the yellow (24V-) LED on the RND20 switches on.
The level relay (RN020) monitors the level of water in the tank through probes.
Whenever the water is no longer in contact with one of the probes due to grease accumulation or lack of water, the RND20 relay arms (10-12) and switches the red light and sound alarm on in the MCS-AL alarm module.
Applications
Control of grease level in tanks Hydrocarbon Separators and Grease Separators